Suntex EC-4110-ICON transmitter provides precise inductive conductivity measurements even in the harshest chemical conditions with chemical concentration curves, or a self-defined conversion table. Built-in product adjustment function allows fine-tuning for concentration values to minimize process contamination caused deviations. Users can even utilize MODBUS digital communication to remotely change concentration curves. The EC-4110-I is an inductive conductivity transmitter without concentration mode
Features
- Compatible with anti-fouling electrodeless conductivity sensor
- Conductivity range up to 2000 mS/cm
- EC-4110-ICON with built-in concentration curves and a self-defined table function
- EC-4110-ICON simultaneously display concentration, compensated conductivity and absolute conductivity values
- EC-4110-I with conductivity, salinity and TDS measurement
- Password protection
Applications
- Chemical Concentration
- Reagent Dilution
- Chemical Recycling
- Food and Beverage CIP
- Scrubber
- Cooling Water
- Salinity Adjustment
- Desalination
Technical Specification
Model | EC-4110-I / (EC-4110-ICON) |
Measuring Mode | Conductivity / TDS / Salinity / Temp / (Concentration) |
Measuring Range | Conductivity: 0.0 uS/cm ~ 2000 mS/cm (Depends on Selected Range; Auto or Fixed >= 1 mS/cm: +/- 1% (+/- 1 Digit), < 1 mS/cm: +/- 10 uS/cm Salinity: 0.0 ppt ~ 70.0 ppt TDS: 0 mg/L (ppm) ~ 19999 mg/L (ppm) ; 0.00 ~ 199.9 ppt Temperature: PT-1000: -30.0~200.0°C; NTC-30K: -30.0~130.0°C, (Depends on the sensor), ±0.2°C (±1 Digit) with temp. error correction function (Concentration): Range incl. different temp. condition; Resolution 0.01%) NaCl_28%: 0~28.% HCl_18%: 0~18% HCl_39%: 22~39% HNO3_30%: 0~30% HNO3_96%: 35 ~ 96% NaOH_24%: 0~24% NaOH_50%: 15~50% H2SO4_37%: 0~37% H2SO4_88%: 28 ~ 88% H2SO4_99%: 89~99% H3PO4_35%: 0~35% User Defined Concentration Table (9 Temp. x 9 Con./Cond. Matrix) |
Temperature compensation | Pt-1000 or NTC 30K automatic compensation Manual temp. compensation, and can display non-compensated conductivity value |
Calibration Mode | (1) Manual cell-constant adjustment (2) Conductivity standard solution calibration (3)Zero-point calibration |
Cell Constant | Freely adjustable 0.008~9.9999 cm-1 |
Product Adjustment | Factor: 0.7000~1.3000 |
Temperature Coefficient | Linear temperature compensation at 0.00%~40.00%, Non-linear compensation and Off-compensation |
Compensated Temperature | 0~200°C, Freely adjustable & setting of the temp. value to be compensated at |
Display | LCM (graphic display) with auto/manual illumination function, Text, Chart, Trace mode |
Calibration Mode | One point or two points calibration |
Analog Output | Isolated DC 0/4 ~ 20mA Corresponding to Measurement, Max Load 500 Ohms |
Serial Interface | RS-485 (MODBUS RTU or ASCII) |
Event Log Book | 50 event records |
Setting Relays | 240 VAC, 0.5A max. (recommended) Hi/Lo, Hi/Hi, Lo/Lo selectable two limited programmable, ON/OFF |
Wash Relay | 240 VAC, 0.5A max. (recommended) On: 0~99min. 59sec, Off: 0~999hr 59min. |
Ambient Temperature | 0 ~ 50°C |
Storage Temperature | -20 ~ 70°C |
Power Supply | 100~240 VAC±10%, 50~60 Hz, 7W Max. |
Installation | Wall mounting, Pipe mounting, Panel mounting |
Dimension | 96 mm x 96 mm x 132 mm (H x W x D), 1/4 DIN |
Cut Out Dimensions | 93 mm x 93 mm (H x W) |
Weight | 0.5 kg |
Protection | IP 65 (NEMA 4X) |
Sensor 8-201-PFA-10 Specification
Type | Inductive |
Measuring Range | 0 ~ 2000 mS/cm |
Working Temperature | -20 ~ 130°C |
Pressure Range | 0 ~ 16 bar |
Sensor Material | PFA |
Sealing Material | FEP |
Temperature Sensor | Pt-1000 |
Cell Constant | 2.7cm-1 |
Process Connection | G 3/4″ |
Min Immersive Depth | 114 mm |
Max Length | 187 mm |
Cable Length | 10m |