INDUCTIVE CONDUCTIVITY / CHEMICAL CONCENTRATION

Suntex EC-4110-ICON transmitter provides precise inductive conductivity measurements even in the harshest chemical conditions with chemical concentration curves, or a self-defined conversion table. Built-in product adjustment function allows fine-tuning for concentration values to minimize process contamination caused deviations. Users can even utilize MODBUS digital communication to remotely change concentration curves. The EC-4110-I is an inductive conductivity transmitter without concentration mode

Features

  • Compatible with anti-fouling electrodeless conductivity sensor
  • Conductivity range up to 2000 mS/cm
  • EC-4110-ICON with built-in concentration curves and a self-defined table function
  • EC-4110-ICON simultaneously display concentration, compensated conductivity and absolute conductivity values
  • EC-4110-I with conductivity, salinity and TDS measurement
  • Password protection

Applications

  • Chemical Concentration
  • Reagent Dilution
  • Chemical Recycling
  • Food and Beverage CIP
  • Scrubber
  • Cooling Water
  • Salinity Adjustment
  • Desalination

Technical Specification

ModelEC-4110-I / (EC-4110-ICON)
Measuring ModeConductivity / TDS / Salinity / Temp / (Concentration)
Measuring RangeConductivity: 0.0 uS/cm ~ 2000 mS/cm (Depends on Selected Range; Auto or Fixed
>= 1 mS/cm: +/- 1% (+/- 1 Digit), < 1 mS/cm: +/- 10 uS/cm
Salinity: 0.0 ppt ~ 70.0 ppt
TDS: 0 mg/L (ppm) ~ 19999 mg/L (ppm) ; 0.00 ~ 199.9 ppt
Temperature: PT-1000: -30.0~200.0°C; NTC-30K: -30.0~130.0°C, (Depends on the sensor),
±0.2°C (±1 Digit) with temp. error correction function
(Concentration): Range incl. different temp. condition; Resolution 0.01%)
NaCl_28%: 0~28.%
HCl_18%: 0~18%
HCl_39%: 22~39%
HNO3_30%: 0~30%
HNO3_96%: 35 ~ 96%
NaOH_24%: 0~24%
NaOH_50%: 15~50%
H2SO4_37%: 0~37%
H2SO4_88%: 28 ~ 88%
H2SO4_99%: 89~99%
H3PO4_35%: 0~35%
User Defined Concentration Table (9 Temp. x 9 Con./Cond. Matrix)
Temperature compensationPt-1000 or NTC 30K automatic compensation
Manual temp. compensation, and can display non-compensated conductivity value
Calibration Mode(1) Manual cell-constant adjustment
(2) Conductivity standard solution calibration
(3)Zero-point calibration
Cell ConstantFreely adjustable 0.008~9.9999 cm-1
Product AdjustmentFactor: 0.7000~1.3000
Temperature CoefficientLinear temperature compensation at 0.00%~40.00%,
Non-linear compensation and Off-compensation
Compensated Temperature0~200°C, Freely adjustable & setting of the temp. value to be compensated at
DisplayLCM (graphic display) with auto/manual illumination function, Text, Chart, Trace mode
Calibration ModeOne point or two points calibration
Analog OutputIsolated DC 0/4 ~ 20mA Corresponding to Measurement, Max Load 500 Ohms
Serial InterfaceRS-485 (MODBUS RTU or ASCII)
Event Log Book50 event records
Setting Relays240 VAC, 0.5A max. (recommended)
Hi/Lo, Hi/Hi, Lo/Lo selectable two limited programmable, ON/OFF
Wash Relay 240 VAC, 0.5A max. (recommended)
On: 0~99min. 59sec, Off: 0~999hr 59min.
Ambient Temperature0 ~ 50°C
Storage Temperature-20 ~ 70°C
Power Supply100~240 VAC±10%, 50~60 Hz, 7W Max.
InstallationWall mounting, Pipe mounting, Panel mounting
Dimension96 mm x 96 mm x 132 mm (H x W x D), 1/4 DIN
Cut Out Dimensions93 mm x 93 mm (H x W)
Weight0.5 kg
ProtectionIP 65 (NEMA 4X)

Sensor 8-201-PFA-10 Specification

TypeInductive
Measuring Range0 ~ 2000 mS/cm
Working Temperature-20 ~ 130°C
Pressure Range0 ~ 16 bar
Sensor MaterialPFA
Sealing MaterialFEP
Temperature SensorPt-1000
Cell Constant2.7cm-1
Process ConnectionG 3/4″
Min Immersive Depth114 mm
Max Length187 mm
Cable Length10m