Suntex SP-2110 and SP-2310 Benchtop pH/ORP/Temp Meter features a graphical interface design, an elegant exterior that seamlessly combines functionality with aesthetics together with Smooth material enhances visual appeal while providing a comfortable tactile experience.
With a USB Type-C port for a stable power supply and connection to a printer. Encompassing various
brands of standard solutions and calibration reminder function provides greater flexibility for calibration.


Features:
- Switch between Celsius and Fahrenheit temperature
- Auto-Read function status indicator light (breathing light)
- Calibration features both linear and segmented calibration modes
- Integrated multi-brand standard solution table for targeted calibration
- An integral pH calibration graph can be displayed after the calibration
- USB Type-C power supply function and the ability to connect to an array printer
- Provides various display options, including calibration standard solutions or real-time potential
- Calibration reminder function can display the remaining calibration days and pop-up notifications
Additional Features for SP-2310 Only
- Provides up to five-point calibration
- Display a 3-minute real-time chart
- Provide setting and calibration passcode function
- Stores up to 60,000 data and 50 calibration records
- Reliable USB Type-C connection for data transfer to the computer
| Measuring Range | pH: -2 ~16pH ORP: -2000~2000mV Temp: -10.0 ~110.0 deg C |
| Resolution | pH: 0.01 pH, +/- 0.01 pH ORP: 0.1 / 1 mV, +/- 0.05% Temp: 0.01, +/- 0.2 deg C |
| Auto Read Function | Yes |
| Auto Power Off | Yes (Built In Timer) |
| Temperature Compensation | Auto NTC30K or PT1000 or Manual Adjustment |
| Calibration | pH: Up to 3 points TECH, NIST, any, Merck, JIS Z8802, Mettler US/EU, Define Buffer ORP: Relative Potential Adjustment Range: +/- 300.0 mV |
| Data Transmitting | USB Type-C interface with RS232 Protocol for Printer |
| Data Storage | None |
| Calibration Record | Only the latest record |
| Display | 4.3″ Graphic LCM Backlight Display with Manual Brightness adjustment function |
| Power Supply | USB Type-C or 6V Power Supply (optional) |
| Dimensions | 194mm x 82mm x 38mm (LxWxH) |
| Weight | 0.5kg |
| Measuring Range | pH: -2 ~20pH ORP: -2000~2000mV Temp: -10.0 ~110.0 deg C |
| Resolution | (SP-2110) pH: 0.01 pH, +/- 0.01 pH ORP: 0.1 / 1 mV, +/- 0.05% Temp: 0.01, +/- 0.2 deg C (SP-2310) pH: 0.001pH, +/-0.001pH ORP: 0.1 / 1 mV, +/- 0.05% Temp: 0.01, +/- 0.2 deg C |
| Auto Read Function | Yes |
| Auto Power Off | Yes (Built In Timer) |
| Temperature Compensation | Auto NTC30K or PT1000 or Manual Adjustment |
| Calibration | pH: (SP-2110) Up to 3 points (SP-2310) Up to 5 points TECH, NIST, any, Merck, JIS Z8802, Mettler US/EU, Define Buffer ORP: Relative Potential Adjustment Range: +/- 300.0 mV |
| Data Transmitting | (SP-2110) USB Type-C interface with RS232 Protocol for Printer (SP-2310) USB Type-C interface with RS232 Protocol for Printer and Computer |
| Data Storage | (SP-2110) Auto/Manual, 200 Sets* (SP-2310) Auto/Manual, 60,000 Sets* * Measurement, Temp, Time, Date, User Group ID, Sample No |
| Calibration Record | (SP-2110) Last 10 Calibration Records (GLP) (SP-2310) Last 50 Calibration Records (GLP) |
| Display | 4.3″ Graphic LCM Backlight Display with Manual Brightness adjustment function |
| Power Supply | USB Type-C or 6V Power Supply (optional) |
| Dimensions | 220mm x 180mm x 65mm (LxWxH) |
| Weight | 0.5 kg |